Our high-performance test system I-TS (Infeed test system) is a high dynamic, bidirectional DC power supply with continuous and seamless transition from source to sink operation. Thanks to the 3-level technology, it off ers an adjustable voltage range of 10 – 1500 V with a center point. The DC channels can also be operated individually or in parallel. The outstanding performance is the basis for a wide range of applications in the automotive, hydrogen and laboratory sectors.

Voltage range 2x 5 – 750 V / 1x 10 - 1500 V

Power in kW Current in A Dimensions (W x D x H in mm)
I-TS-3872-1500-300-1000 300 1000 2400 x 800 x 2200
I-TS-3872-1500-600-1000 600 1000 4800 x 800 x 2200

General technical dataI-TS-3872

AC mains voltage
AC mains frequency
380 / 400 V ± 10 %, 3-phase, PE, 50 / 60 Hz ±5 %
Measurement accuracy Voltage: 16 Bit ADC // Current: 16 Bit ADC
Ripple voltage / current ≤ 0,1 % eff . fs
Voltage tolerance dynamic
(0-100 % INom in 3 ms)
Battery tester < 3 %
Battery emulator < 1 %
Short circuit performance Short circuit proof:
Icw: 4,5 kA
Permissible environmental conditions:
Storage as per EN 60721-3-1
Transport as per EN 60721-3-2
Operation as per EN 60721-3-3
1K21 / 1M11, +5 to +40 °C
2K12 / 2M4, -25 to +70 °C
3K22 / 3M11, +5 to +40 °C
Cooling method Enforced water cooling (IP54)
Safety of machinery -
Safety-related parts of control systems
EN ISO 13849-1
EN ISO 13849-2
Safety of machinery EN 60204-1 Exception:
• Sec. 11.3 Protection type see Techn. Data
• Sec. 13.2 Identifi cation of conductor
EMC standards EN 61000-2-4 Class 3
EN 61000-6-2
EN 61000-6-4

Standard features

The I-TS-3872 impresses even in the standard system configuration with its extensive equipment and is therefore ready for immediate use by customers from all over the world. The following is a small excerpt:

Allgemeine Daten

  • ■ Input voltage 380 / 400 V, 50 / 60 Hz
  • ■ Sense connections for voltage measurement / regulation
  • ■ DC current and voltage measurement with 0.1 %
    full scale accuracy
  • ■ Switchable battery tester / battery emulator version
  • ■ Protection class IP54
  • ■ Water cooling
  • ■ Integrated water/water heat exchanger
  • ■ Plug and Play parallelization of two I-TS 3872
    with the same technical data

Safety features

  • ■ Lockable main switch as load-break switch
  • ■ Safety control for Performance Level d in accordance with
    EN 60204-1 / ISO 13849-1.
  • ■ Voltmeter and indicator light in cabinet door
  • ■ Redundant DC output contactors
  • ■ Connection terminals for external „emergency stop“
  • ■ 2x connection terminals for external „Stop“
  • ■ 1x connection terminals for external
    „operating mode selection“
  • ■ DC output electrically isolated
  • ■ 2x insulation monitoring devices (separately switchable)

Interfaces

  • ■ 10 inch display with touch operation
  • ■ Modbus / TCP interface
  • ■ CAN interface
  • ■ VNC interface

Options (extract)

  • ■ 2x fi eldbus interfaces EtherCAT or Profi net IO or Profi bus DP (one per channel)
  • ■ Door lock
  • ■ Fail-safe feedback:Emergency stop, stop, DC output contactors open (no individual selection possible)