PRODUCTS

High Performance High Power Bidirectional
Programmable DC Power Supply
biTRITON-B
TRBC Series

Product Introduction

TRBC series is a high power bidirectional programmable DC power supply with dual quadrant, integrating bidirectional power supply and regenerative load to supply and absorb current. With the design of wide range and high power density, voltage range 0~2250V, output power up to 42kW in 3U chassis, it covers a wide range of DUT test applications. TRBC series are equipped with fast dynamic response, high accuracy output and measurement functions, and can also be configured with photovoltaic simulation, battery simulation and other software to help users realize accurate and efficient testing in multiple scenarios.

Application Fields

  • ■ Laboratory, production line ATE automatic test system
  • ■ Photovoltaic inverter, hydrogen fuel cell, solar cell matrix and other new energy fields
  • ■ Energy storage converter, UPS, photovoltaic storage machine and other energy storage fields
  • ■ BOBC, DC-DC, motor drive, charging pile and other automotive fields
  • ■ Charge/discharge test for power batteries, lead batteries, supercapacitors, etc.
  • ■ Test for aerospace electronics, high-power communications equipment, drones, etc.

Main Features

  • ■ High power density, up to 42kW output in 3U chassis
  • ■ Wide output range, one can be used as multiple
  • ■ High-speed dynamic response, voltage rise and fall time ≤ 5ms
  • ■ Voltage accuracy: 0.02%+0.02%F.S.; Current accuracy: 0.1%+0.1%F.S.
  • ■ CC & CV Priority suitable for all types of test item
  • ■ Master/Master perallel up to MW level
  • ■ Load mode support CC/CV/CP/CR function
  • ■ Battery simulation, charge/discharge test, sequence test, waveform function etc.
  • ■ PV array I-V curve simulation function (optional)
  • ■ 6.8 inch LCD screen for clear test information
  • ■ Standard with LAN/RS232/RS485/CAN communication
  • ■ Modbus-RTU, SCPI, CANopen protocol supportable

Seamless switch between source and load to regenerate energy

With the integration of power supply and regenerative load, TRBC series bidirectional power supply can be converted continuously seamlessly between the output and absorbed current, effectively avoiding voltage or current overshoot. TRBC series can not only provide external power, but also absorb power, and return electric energy to the grid cleanly, the regenerative efficiency up to 93%. It is widely used in lithium battery, UPS, BOBC and other equipment testing.

PV Cell Simulation (Optional)

With the characteristics of accurate measurement, high stability, fast response speed, TRBC series DC power supply with PV Cell Simulation can accurately simulate the I-V, P-V curve of the solar cell matrix. After setting Vmp, Pmp and other parameters, it can generate reports in compliance with regulations, which is used to test the static and dynamic maximum power tracking efficiency of PV inverters, and also can provide support for system simulation and core equipment testing of microgrids, distributed photovoltaic and other power systems.

Battery Simulation

TRBC series with battery simulator software to meet the user's needs for different types of battery simulation, and improve the test efficiency. battery simulator software has 7 standard battery model libraries, users only need to select the corresponding battery type, configure the basic capacity and protection parameters, the software can quickly generate the corresponding type of battery characteristic curve; And there are 2 types of custom battery characteristic curve, engineers can be based on the actual measurement of the battery curve data, import the data into the software and carry out simulation.

Wide range, high power density for saving cost and space

TRBC series DC power supply adopts systematic heat dissipation design, optimised device selection, main circuit topology, system heat dissipation, to achieve 42kW power output in 3U chassis, and adopts wide range output design, voltage up to 2250V, current up to 65A. With wide range and high power density design, TRBC series satisfy engineers' test application scenarios for products of various voltage/ current levels, and greatly reducing purchase cost and space occupancy in laboratory or automated test systems.

CC & CV priority function

TRBC series has the function of setting voltage-control priority or current-control loop priority, it can adopt the optimal working mode for testing according to the characteristics of DUT, so as to better protect DUT.As shown in Figure 1, when it needs to reduce voltage overshoot during testing, such as powering a DC-DC power module, the voltage priority mode should be used to obtain a fast and smooth rising voltage. As shown in Figure 2, when it needs to reduce current overshoot during testing or the component to be measured is low impedance such as in the battery charging scenario, the current priority mode should be used to obtain a fast and smooth rising current.

Quick Selection

500V ModelSpecificationSize
TRBC-500-65-143500V/65A/14kW19inch/3U
TRBC-500-130-223500V/130A/22kW19inch/3U
TRBC-500-180-323500V/180A/32kW19inch/3U
TRBC-500-195-423500V/195A/42kW19inch/3U
TRBC-500-360-643500V/360A/64kW19inch/6U
TRBC-500-390-843500V/390A/84kW19inch/6U
TRBC-500-585-1263500V/585A/126kW19inch/9U
TRBC-500-780-1683500V/780A/168kW19inch/12U
TRBC-500-975-2103500V/975A/210kW19inch/15U
TRBC-500-1170-2523500V/1170A/252kW19inch/18U
1000V ModelSpecificationSize
TRBC-1000-65-2831000V/65A/28kW19inch/3U
TRBC-1000-130-5631000V/130A/56kW19inch/6U
TRBC-1000-195-8431000V/195A/84kW19inch/9U
TRBC-1000-260-11231000V/260A/112kW19inch/12U
TRBC-1000-325-14031000V/325A/140kW19inch/15U
TRBC-1000-390-16831000V/390A/168kW19inch/18U
TRBC-1000-455-19631000V/455A/196kW19inch/21U
TRBC-1000-520-22431000V/520A/224kW19inch/24U
TRBC-1000-585-25231000V/585A/252kW19inch/27U
TRBC-1000-650-28031000V/650A/280kW19inch/30U
1500V ModelSpecificationSize
TRBC-1500-60-2231500V/60A/22kW19inch/3U
TRBC-1500-60-3231500V/60A/32kW19inch/3U
TRBC-1500-65-4231500V/65A/42kW19inch/3U
TRBC-1500-120-6431500V/120A/64kW19inch/6U
TRBC-1500-130-8431500V/130A/84kW19inch/6U
TRBC-1500-195-12631500V/195A/126kW19inch/9U
TRBC-1500-260-16831500V/260A/168kW19inch/12U
TRBC-1500-325-21031500V/325A/210kW19inch/15U
TRBC-1500-390-25231500V/390A/252kW19inch/18U
TRBC-1500-455-29431500V/455A/294kW19inch/21U
TRBC-1500-520-33631500V/520A/336kW19inch/24U
TRBC-1500-585-37831500V/585A/378kW19inch/27U
TRBC-1500-650-42031500V/650A/420kW19inch/30U
2250V ModelSpecificationSize
TRBC-2250-60-2232250V/60A/22kW19inch/3U
TRBC-2250-60-3232250V/60A/32kW19inch/3U
TRBC-2250-65-4232250V/65A/42kW19inch/3U
TRBC-2250-120-6432250V/120A/64kW19inch/6U
TRBC-2250-130-8432250V/130A/84kW19inch/6U
TRBC-2250-195-12632250V/195A/126kW19inch/9U
TRBC-2250-260-16832250V/260A/168kW19inch/12U
TRBC-2250-325-21032250V/325A/210kW19inch/15U
TRBC-2250-390-25232250V/390A/252kW19inch/18U
TRBC-2250-455-29432250V/455A/294kW19inch/21U
TRBC-2250-520-33632250V/520A/336kW19inch/24U
TRBC-2250-585-37832250V/585A/378kW19inch/27U
TRBC-2250-650-42032250V/650A/420kW19inch/30U

Product Dimension

Technical Data Sheet (1)

Model TRBC-500-65-143 TRBC-500-130-223 TRBC-500-180-323 TRBC-500-195-423
Voltage 0~500V
Current -65A~+65A -130A~+130A -180A~+180A -195A~+195A
Power-14kW~+14kW-22kW~+22kW-32kW~+32kW -42kW~+42kW
CV Mode
Range0~500V
Setting Resolution1mV
Setting Accuracy(23±5°C)≤0.02% + 0.02% F.S.
Voltage Ripple (20Hz–20MHz)<3Vp-p
≤0.4Vrms
CC Mode
Range -65A~+65A -130A~+130A-180A~+180A -195A~+195A
Setting Resolution0.1mA 1mA
Setting Accuracy(23±5°C)≤0.1% + 0.1% F.S.
Current Ripple (20Hz–20MHz)≤1.4Ap-p ≤2Ap-p
≤200mArms
CP Mode
Range-14kW~+14kW-22kW~+22kW-32kW~+32kW -42kW~+42kW
Setting Resolution0.1W
Setting Accuracy(23±5°C)≤0.1% + 0.1% F.S.
Voltage Measurement
Range0~500V
Readback Resolution1mV
Readback Accuracy (23±5°C)≤0.02% + 0.02% F.S.
Temperature Coefficient≤15ppm/°C
Current Measurement
Range-65A~+65A-130A~+130A-180A~+180A -195A~+195A
Readback Resolution0.1mA1mA
Readback Accuracy (23±5°C)≤0.1% + 0.1% F.S.
Temperature Coefficient:≤30ppm/°C
Dynamic Characteristics
Voltage Rise Time (no load 10%→90%)≤5ms
Voltage Rise Time (full load 10%→90%)≤5ms
Voltage Fall Time (no load 90%→10%)≤10ms
Voltage Fall Time (full load 90%→10%)≤5ms
Transient Response TimeThe recovery time of load varying from 10% to 60% and output voltage recovering within 0.75% of rated voltage is less than 1ms.
Line Regulation
Voltage<0.01% F.S.
Current<0.02% F.S.
Load Regulation
Voltage<0.01% F.S.
Current<0.05% F.S.
Others
Isolation (Output to ground):1000V DC
Max. Efficiency93%
Power Factor0.99
Protection OVP/OCP/OPP/UVP/UCP
Interface LAN / RS232 / RS485 / CAN
Communication Response Time 5ms
AC Input Three phase 340VAC480VAC, 47Hz63Hz, ≤25A Three phase 340VAC480VAC, 47Hz63Hz, ≤40A Three phase 340VAC480VAC, 47Hz63Hz, ≤55A Three phase 340VAC480VAC, 47Hz63Hz, ≤70A
Temperature Operating temperature: 0°C50°C (>35°C derating output); Storage temperature: -10°C70°C
Operating Environment Altitude <2000m; relative humidity:5%~90%RH(non-condensing); atmospheric pressure: 80~110kPa
Dimension 132.0mm(H)*482.0mm(W)*755.0mm(D)(with shield
Net Weight Approx. 34kg Approx. 42kg

Note 1: Voltage fall time in ON state.
Note 2: For other specifications, please contact Headspring.
Note 3: All specifications are subject to change without notice.

Technical Data Sheet (2)

Model TRBC-1000-65-283
Rated Voltage 0~1000V
Current -65A~+65A
Power -28kW~+28kW
CV Mode
Range0~1000V
Setting Resolution10mV
Setting Accuracy (23±5°C)≤0.02% + 0.02% F.S.
Voltage Ripple (20Hz–20MHz) <3Vp-p
≤0.4Vrms
CC Mode
Range -65A~+65A
Setting Resolution0.1mA
Setting Accuracy (23±5°C)≤0.1% + 0.1% F.S.
Current Ripple (20Hz–20MHz) ≤1.4Ap-p
≤200mArms
CP Mode
Range-28kW~+28kW
Setting Resolution 0.1W
Setting Accuracy (23±5°C)≤0.1% + 0.1% F.S.
Voltage Measurement
Range0~1000V
Readback Resolution10mV
Readback Accuracy(23±5°C)≤0.02% + 0.02% F.S.
Temperature Coefficient≤15ppm/°C
Current Measurement
Range-65A~+65A
Readback Resolution0.1mA
Readback Accuracy (23±5°C)≤0.1% + 0.1% F.S.
Temperature Coefficient≤30ppm/°C
Dynamic Characteristics
Voltage Rise Time (no load 10%→90%):≤5ms
Voltage Rise Time (full load 10%→90%):≤5ms
Voltage Fall Time (no load 90%→10%): ≤10ms
Voltage Fall Time (full load 90%→10%):≤5ms
Transient Response Time:The recovery time of load varying from 10% to 60% and output voltage recovering within 0.75% of rated voltage is less than 1ms.
Line Regulation
Voltage:<0.01% F.S.
Current:<0.02% F.S.
Load Regulation
Voltage:<0.01% F.S.
Current:<0.05% F.S.
Others
Isolation (Output to ground): 1500V DC
Max. Efficiency:93%
Power Factor:0.99
Protection:OVP / OCP / OPP / UVP / UCP
Interface:LAN / RS232 / RS485 / CAN
Communication Response Time:5ms
AC Input Three phase 340VAC~480VAC, 47Hz~63Hz, <50A
Temperature Operating temperature: 0°C~50°C(>35°C derating output); Storage temperature: -10°C~70°C
Operating Environment Altitude <2000m; relative humidity: 5%~90%RH(non-condensing); atmospheric pressure: 80~110kPa
Dimension 132.0mm(H)*482.0mm(W)*755.0mm(D)(with shield
Net Weight Approx. 38kg

Note 1: Voltage fall time in ON state.
Note 2: For other specifications, please contact Headspring.
Note 3: All specifications are subject to change without notice.

Technical Data Sheet (3)

Model TRBC-1500-60-223 TRBC-1500-60-323 TRBC-1500-65-423
Voltage Voltage 0~1500V
Current -60A~+60A -65A~+65A
Power -22kW~+22kW -32kW~+32kW -42kW~+42kW
CV Mode
Range 0~1500V
Setting Resolution10mV
Setting Accuracy(23±5°C) ≤0.02% + 0.02% F.S.
Voltage Ripple(20Hz-20MHz) <3Vp-p
≤0.4Vrms
CC Mode
Range-60A~+60A -65A~+65A
Setting Resolution 0.1mA
Setting Accuracy (23±5°C) 0.1%±0.1%F.S.
Current Ripple(20Hz-20MHz)≤1.4Ap-p
≤200mArms
CP Mode
Range-22kW~+22kW -32kW~+32kW -42kW~+42kW
Setting Resolution 0.1W
Setting Accuracy(23±5°C) ≤0.1% + 0.1% F.S.
Voltage Measurement
Range 0~1500V
Readback Resolution10mV
Setting Accuracy (23±5°C)≤0.02% + 0.02% F.S.
Temperature Coefficient≤15ppm/°C
Current Measurement
Range -60A~+60A -65A~+65A
Readback Resolution0.1mA
Setting Accuracy (23±5°C) ≤0.1% + 0.1% F.S.
Temperature Coefficient≤30ppm/°C
Dynamic Characteristics
Voltage Rise Time (no load 10%~90%) ≤5ms
Voltage Rise Time(full load 10%~90%≤5ms
Voltage Fall Time (no load 90%~10%)≤10ms
Voltage Fall Time(full load 90%~10%) ≤5ms
Transient Response TimeThe recovery time of load varying from 10% to 60% and output voltage recovering within 0.75% of rated voltage is less than 500μs.
Line Regulation
Voltage<0.01%F.S.
Current<0.02%F.S.
Load Regulation
Voltage<0.01%F.S.
Current<0.05% F.S.
Others
Isolation (Output to ground)2250V DC
Max. Efficiency93%
Power Factor0.99
Protection OVP/OCP/OPP/UVP/UCP
Interface LAN/RS232/RS485/CAN
Communication Response Time5ms
AC Input Three phase 340VAC~480VAC,47Hz~63Hz,≤40A Three phase 340VAC~480VAC, 47Hz~63Hz,≤55A Three phase 340VAC~480VAC,47Hz~63Hz,≤70A
Temperature Operating temperature: 0°C~50°C(>35°C derating output); Storage temperature:-10°C~70°C
Operating Environment Altitude <2000m; relative humidity: 5%~90%RH(non-condensing); atmospheric pressure: 80~110kPa
Dimension 132.0mm(H)*482.0mm(W)*755.0mm(D)(with shield
Net Weight Approx. 42kg

Note 1: Voltage fall time in ON state.
Note 2: For other specifications, please contact Headspring.
Note 3: All specifications are subject to change without notice.

Technical Data Sheet (4)

Model TRBC-2250-60-223 TRBC-2250-60-323 TRBC-2250-65-423
Rated Voltage 0~2250V
Current -60A~+60A -65A~+65A
Power -22kW~+22kW -32kW~+32kW -42kW~+42kW
CV Mode
Range 0~2250V
Setting Resolution10mV
Setting Accuracy(23±5°C)≤0.02% + 0.02% F.S.
Voltage Ripple(20Hz-20MHz) <3Vp-p
≤0.4Vrms
CC Mode
Range-60A~+60A -65A~+65A
Setting Resolution 0.1mA
Setting Accuracy (23±5°C)≤0.1% + 0.1% F.S.
Current Ripple(20Hz-20MHz)≤1.4Ap-p
≤200mArms
CP Mode
Range-22kW~+22kW -32kW~+32kW -42kW~+42kW
Setting Resolution 0.1W
Setting Accuracy(23±5°C) ≤0.1% + 0.1% F.S.
Voltage Measurement
Range 0~2250V
Readback Resolution10mV
Setting Accuracy (23±5°C)≤0.02% + 0.02% F.S.
Temperature Coefficient≤15ppm/°C
Current Measurement
Range -60A~+60A -65A~+65A
Readback Resolution0.1mA
Readback Accuracy (23±5°C) ≤0.1% + 0.1% F.S.
Temperature Coefficient≤30ppm/°C
Dynamic Characteristics
Voltage Rise Time (no load 10%~90%) ≤5ms
Voltage Rise Time(full load 10%~90%≤5ms
Voltage Fall Time (no load 90%~10%)≤10ms
Voltage Fall Time(full load 90%~10%) ≤5ms
Transient Response TimeThe recovery time of load varying from 10% to 60% and output voltage recovering within 0.75% of rated voltage is less than 500μs.
Line Regulation
Voltage<0.01%F.S.
Current<0.02%F.S.
Load Regulation
Voltage<0.01%F.S.
Current<0.05% F.S.
Others
Isolation (Output to ground)2250V DC
Max. Efficiency93%
Power Factor0.99
ProtectionOVP / OCP / OPP / UVP / UCP
InterfaceLAN / RS232 / RS485 / CAN
Communication Response Time5ms
AC Input Three phase 340VAC480VAC, 47Hz63Hz, ≤40A

Three phase 340VAC480VAC, 47Hz63Hz, ≤55A Three phase 340VAC480VAC, 47Hz63Hz, ≤70A
Temperature Operating temperature: 0°C~50°C(>35°C derating output); Storage temperature:-10°C~70°C
Operating Environment Altitude <2000m; relative humidity: 5%~90%RH(non-condensing); atmospheric pressure: 80~110kPa
Dimension 132.0mm(H)*482.0mm(W)*755.0mm(D)(with shield)
Net Weight Approx. 42kg

Note 1: Voltage fall time in ON state.
Note 2: For other specifications, please contact Headspring.
Note 3: All specifications are subject to change without notice.